China Suppliers Factory Semi-Conductive Water Blocking Tape for Power Cables - Non-Corrosive and Durable
Product Description
Semi conductive water hose for cables is an auxiliary material specially designed for cables (especially medium, high, and ultra-high voltage power cables and other control, communication, signal, and instrumentation cables with shielding requirements). It combines semi conductive performance and water blocking function, which is of greater significance for the safe operation and extended service life of cables. The following is a detailed introduction to the use of semiconductor resistance water hoses for cables:
1. Structure and Composition
The semi conductive water strip for cables is usually composed of two layers of non-woven fabric strips with an intermediate layer of expansion resistant water powder (or absorbent resin), and some products are also soaked and dried to form a semi conductive adhesive. This structure enables the waterproof tape to have both the functions of water absorption and expansion, water resistance, and semi conductivity, which can effectively reduce the accumulation of charges on the insulation surface of the cable and reduce the possibility of partial discharge.
2. Technical features
3. Application Fields
Semi conductive water hoses for cables are widely used in the manufacturing of medium, high, and ultra-high voltage power cables and other cables with shielding requirements in the fields of power, communication, transportation, and construction. It can not only improve the waterproof performance of cables, but also optimize the electrical structure of cables, reduce cable failure rates, and extend cable service life.
4. Performance indicators
The performance indicators of semi conductive water hoses for cables usually include thickness, unit weight, tensile strength, elongation, expansion rate, expansion height, surface resistance, volume resistance, instantaneous stability, long-term stability, and moisture content. These indicators are of great significance for evaluating the performance and effectiveness of water barriers.
5. Precautions
Parameters
Common Specification Table
| Properties | Double-layer | Single-layer | ||||
|---|---|---|---|---|---|---|
| 30 | 40 | 50 | 30 | 40 | 50 | |
| Thickness | 0.3±0.03 | 0.4±0.03 | 0.5±0.03 | 0.3±0.03 | 0.4±0.03 | 0.5±0.03 |
| Grammage(g/m²) | 130±10 | 140±10 | 170±10 | 120±10 | 110±10 | 170±10 |
| Tensile strength(N/cm) | ≥30 | ≥30 | ≥40 | ≥30 | ≥30 | ≥40 |
| Elongation(%) | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 | ≥12 |
| Surface resistance(Ω) | ≤1000 | ≤1000 | ≤1000 | ≤1000 | ≤1000 | ≤1000 |
| Volume Resistance(Ω.cm) | ≤1X10⁵ | ≤1X10⁵ | ≤1X10⁵ | ≤1X10⁵ | ≤1X10⁵ | ≤1X10⁵ |
| Expansion rate(mm/min) | ≥8 | ≥8 | ≥10 | ≥6 | ≥8 | ≥10 |
| Expansion height(mm/3min) | ≥12 | ≥12 | ≥14 | ≥8 | ≥10 | ≥14 |
| Short term stability(℃) | 230 | 230 | 230 | 230 | 230 | 230 |
| Long term stability(℃) | 90 | 90 | 90 | 90 | 90 | 90 |
| Moisture(%) | ≤9 | ≤9 | ≤9 | ≤9 | ≤9 | ≤9 |
| Application | Used for water blocking between various components of power cables, non corrosive. Due to the absence of a cover cloth barrier, the water blocking performance is better. | |||||
| Support customizing other specifications | ||||||
Detailed image

Fillers Series
Tapes Series