Introducing our advanced semi-conductive water blocking tape, specially designed for power cable applications. Manufactured in China by leading suppliers, this tape features a unique composition of semiconductor materials, electrode silver paste, and a durable substrate. Its innovative design allows the tape to adjust its resistance value in response to varying electric field strengths, ensuring optimal water resistance between crucial cable components. As a product from a reputable factory, it maintains exceptional quality while being non-corrosive, making it a reliable choice for all your power cable needs

    Product Description

    Semi conductive water hose for cables is an auxiliary material specially designed for cables (especially medium, high, and ultra-high voltage power cables and other control, communication, signal, and instrumentation cables with shielding requirements). It combines semi conductive performance and water blocking function, which is of great significance for the safe operation and extended service life of cables. The following is a detailed introduction to the use of semiconductor resistance water hoses for cables:

    1. Structure and Composition

    The semi conductive water strip for cables is usually composed of two layers of non-woven fabric strips with an intermediate layer of expansion resistant water powder (or absorbent resin), and some products are also soaked and dried to form a semi conductive adhesive. This structure enables the waterproof tape to have both the functions of water absorption and expansion, water resistance, and semi conductivity, which can effectively reduce the accumulation of charges on the insulation surface of the cable and reduce the possibility of partial discharge.

    2. Technical Features

    Semi conductive performance: The water barrier tape has a low electrical resistivity and can serve as an electrical connection in the cable, helping to optimize the electrical structure of the cable and reduce electric field distortion and partial discharge.
    Water blocking performance: Water absorbing resin can rapidly expand upon contact with water, forming a waterproof barrier that effectively prevents moisture from further penetrating into the interior of the cable.
    High mechanical strength: Waterproof tapes usually have high tensile strength and elongation at break, which can withstand the mechanical stress of cables during installation and operation.
    Good heat resistance: The product has excellent heat resistance and can maintain stable electrical and physical properties at high temperatures.
    Easy to process: The waterproof tape is easy to wrap and longitudinally wrap, and can be conveniently applied in the manufacturing process of various cables.

    3. Application Fields

    Semi conductive water hoses for cables are widely used in the manufacturing of medium, high, and ultra-high voltage power cables and other cables with shielding requirements in the fields of power, communication, transportation, and construction. It can not only improve the waterproof performance of cables, but also optimize the electrical structure of cables, reduce cable failure rates, and extend cable service life.

    4. Performance Indicators

    The performance indicators of semi conductive water hoses for cables usually include thickness, unit weight, tensile strength, elongation, expansion rate, expansion height, surface resistance, volume resistance, instantaneous stability, long-term stability, and moisture content. These indicators are of great significance for evaluating the performance and effectiveness of water barriers.

    5. Precautions

    Choose the appropriate waterproof tape: Select the appropriate waterproof tape material and specifications according to the specific requirements of the cable, ensuring that its electrical, waterproof, and mechanical properties meet the requirements.
    Strict control of process: In the cable manufacturing process, it is necessary to strictly control the process parameters such as the winding tension and overlap rate of the waterproof layer to ensure the uniformity and continuity of the waterproof layer.
    Quality inspection: Conduct strict electrical and water blocking performance tests on the manufactured cables to ensure that the water blocking tape plays its due role in the cables.
    Semi-conductive resistance hose - Introductionl26
    电缆用主图60e8

    Parameters

    Properties Double-layer Single-layer
    30 40 50 30 40 50
    Thickness 0.3±0.03 0.4±0.03 0.5±0.03 0.3±0.03 0.4±0.03 0.5±0.03
    Grammage (g/m²) 130±10 140±10 170±10 120±10 110±10 170±10
    Tensile strength (N/cm) ≥30 ≥30 ≥40 ≥30 ≥30 ≥40
    Elongation (%) ≥12 ≥12 ≥12 ≥12 ≥12 ≥12
    Surface resistance (Ω) ≤1000 ≤1000 ≤1000 ≤1000 ≤1000 ≤1000
    Volume Resistance (Ω.cm) ≤1X10⁵ ≤1X10⁵ ≤1X10⁵ ≤1X10⁵ ≤1X10⁵ ≤1X10⁵
    Expansion rate (mm/min) ≥8 ≥8 ≥10 ≥6 ≥8 ≥10
    Expansion height (mm/3min) ≥12 ≥12 ≥14 ≥8 ≥10 ≥14
    Short term stability (°C) 230 230 230 230 230 230
    Long term stability (°C) 90 90 90 90 90 90
    Moisture (%) ≤9 ≤9 ≤9 ≤9 ≤9 ≤9
    Application Used for water blocking between various components of power cables, non corrosive. Due to the absence of a cover cloth barrier, the water blocking performance is better.
    Support customizing other specifications

    Detailed Image

    PE Black Belt Workshopp7c

    Frequently Asked Questions (FAQ)

    What is the primary function of the semi conductive water hose/tape for cables?
    It combines semi-conductive performance with water-blocking functions. It helps optimize the electrical structure of cables, reduces electric field distortion, and prevents water/moisture penetration, thereby extending the service life of cables.
    What is the typical composition of these water blocking tapes?
    They are usually composed of two layers of non-woven fabric strips with an intermediate layer of expansion-resistant water powder or absorbent resin. Some variants are also treated to form a semi-conductive adhesive.
    In which fields are these cable tapes applied?
    They are widely applied in medium, high, and ultra-high voltage power cables, and other shielded cables used in the power, communication, transportation, and construction industries.
    What are the key performance indicators of the water barrier?
    Key indicators include thickness, unit weight (grammage), tensile strength, elongation, expansion rate and height, surface and volume resistance, moisture content, and short/long-term thermal stability.
    What precautions should be taken during the manufacturing process?
    Manufacturers must select the correct tape specifications, strictly control parameters like winding tension and overlap rate to ensure a uniform layer, and perform rigorous electrical and water-blocking quality tests.